Features
KLARI-PROBESare the convenient measuring units for low voltage Klaric modules up to 80V.
For current measurements the PROBES are equipped with low resistive accuracy resistors, for voltage measurements with voltage dividers. Temperature measurements are executed with PT1000 resistance thermometers which are also available in acid resistant version.
AllKLARI-PROBEShave a memory device with a communication cable to the module. Therefore the configuration data (type, adjustment values, serial number etc.) are read out of the PROBE and transmitted to the module.
The adjustment values are considered for the measurement result calculation. This implicates a very high degree of accuracy.
Because the shunts only have marginal temperature drift, temperature compensation is not needed.
A factory calibration is included in scope of delivery. On request we are pleased to offer a DAkkS calibration.
Versions
LI-PROBES:These PROBES are used to measure currents in range of 0,25μA…150A (peak current). The user has to take care of protecting the measuring circuit.
MICRO2- / MICRO3-PROBES:Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit/s is/are protected in the ranges of 5…30A by 1 or 2 FK1 fuse/s with the equivalent current value/s like the original fuse/s.
FK1- / FK2- / FK3-PROBES:Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit is protected in the ranges of ?5…70A by the original fuse.
MCASE- / JCASE-PROBES:Current measurements at defined electric circuits inside vehicle fuse box. The measuring circuit is protected in the ranges of 20…60A by 1 JCASE fuse with the equivalent current value like the original fuse.
HI-PROBES:Depending on the selected PROBE current measurements may be performed in ranges of 2,5mA…+7.200/-3.000A (peak current when using a 100μΩ-Shunt). The user has to take care of protecting the measuring circuit.
U-PROBES:With these PROBES voltage measurements are available in ranges of 170μV…+/- 80V.
LI/U-PROBES: ThesePROBES consist of a voltageanda current PROBEwith same potential. It allows current measuring in range of μA…150A (peak current) and also voltage measuring in range of mV…+/- 80V. The user has to take care of protecting the measuring circuit.
HI/U-PROBES:These PROBES consist of a voltage and a current PROBE with same potential. It allows current measuring in range of μA…1.500A (peak current) and also voltage measuring in range of mV…+/- 1000V. The user has to take care of protecting the measuring circuit.
T-PROBES:With these PROBES temperature measurements are available in range of -40…+105°C.
COMBI-PROBES - LI/U - PROBES
HV-LI/U – PROBES consist of a voltage- ?anda current-PROBE.
Current measurement:
The measuring shunt is placed in a potted casing with cable lead-out for looping-in the PROBE into the measuring circuit.
The protection of the measuring circuit has to be provided by the user.
Voltage measurment:
The voltage is measured via a voltage divider.
The input voltage is reduced to an allowed voltage level for the modules.
PROBE-construction:
potted casing ?with integrated shunt (type PBV) and voltage divider.
memory device, used for PROBE-identification and calibration data (placed in connector)
I-PROBE, measuring lines for measuring current = L1 (2 x 1m), heat resistant and highly flexible with loose cable ends
U-PROBE, connection-cable for measuring voltage = L3 (0,5m) with loose cable ends
data cable = L2 (1 / 3 / 5m) with 7-pin plug-connector
Caution: The maximum continuous current is lower than the measuring range.
Please refer to the user manual.
N?here Informationen entnehmen Sie bitte dem Datenblatt.
COMBI-PROBES - I/U-BF1 – PROBES
HV-I/U – PROBES consist of a voltage-anda current-PROBE.
Current measurement:
The measuring shunt is placed via mounting straps directly into the measuring circuit
The protection of the measuring circuit has to be provided by the user
Voltage measurment:
The voltage is measured via a voltage divider
The input voltage is reduced to an allowed voltage level for the modules
PROBE-construction:
shunt (type BF1) with mounting straps (temperature range -40…+130°C) and voltage divider
memory device, used for PROBE-identification and calibration data (placed in connector)
U-connection-cable = L3 (0,5m), heat resistant and highly flexible with loose cable ends
data cable = L2 (1 / 3 / 5m) with 7-pin plug-connector
Caution: The maximum continuous current is lower than the measuring range.
Please refer to the user manual.
COMBI-PROBES - I/U-BF2 – PROBES
HV-I/U – PROBES consist of a voltage-anda current-PROBE.
Current measurement:
The measuring shunt is placed via mounting straps directly into the measuring circuit
The protection of the measuring circuit has to be provided by the user
Voltage measurment:
The voltage is measured via a voltage divider
The input voltage is reduced to an allowed voltage level for the modules
PROBE-construction:
shunt (type BF2) with mounting straps (temperature range -40…+130°C) and voltage divider
memory device, used for PROBE-identification and calibration data (placed in connector)
U-connection-cable = L3 (0,5m), heat resistant and highly flexible with loose cable ends
data cable = L2 (1 / 3 / 5m) with 7-pin plug-connector
Caution: The maximum continuous current is lower than the measuring range.
Please refer to the user manual.
LI - PROBES
Measuring unit with cable lead-out for looping the PROBE into the measuring circuit. The protection of the measuring circuit has to be provided by the user. The shunt is integrated in a grouted casing.
Construction:
cable lead-out = L1 (1m), (heat resistant and highly flexible) with loose cable ends
grouted casing with integrated shunt
data cable = L2 (1…5 m) with 6-pin push-pull connector
memory device, used for PROBE-identification and calibration data
Caution: The maximum continuous current is lower than the measuring range.
Please refer to the user manual.
MICRO2 - PROBES
Measuring unit with MICRO2 connector, which is plugged into the vehicle’s fuse holder instead of the original fuse. The measuring circuit is protected by a FK1 fuse with the equivalent current value to ensure that the measuring circuit is protected. The FK1 fuse is plugged into the fuse holder at the aluminiumcasing. The measuring shunt is integrated in the casing.
Construction:
MICRO2 connector
cable with fuse = L1 (highly flexible and heat resistant)
aluminium casing with integrated shunt and fuse holder for measuring circuit protection
data cable = L2 (1…5m) with 6-pin push-pull-connector
memory device, used for PROBE-identification and calibration data
Caution: The maximum continuous current may be lower than the measuring range.
Please refer to the user manual.
MICRO3 - PROBES
Measuring unit with MICRO3 connector, which is plugged into the vehicle’s fuse holder instead of the original fuse. The measuring circuits are protected by 2 FK1 fuses with the equivalent current values to ensure that the measuring circuits are protected. The FK1 fuses are plugged into the fuse holders at the aluminium casing. The 2 measuring shunts are integrated in the casing.
Construction:
MICRO3 connector
cable with fuse = L1 (highly flexible and heat resistant)
aluminium casing with integrated 2 shunts and 2 fuse holders for measuring circuit protection
data cable = L2 (1…5m) with 6-pin push-pull-connector
memory device, used for PROBE-identification and calibration data
Caution: The maximum continuous current may be lower than the measuring range.
Please refer to the user manua
FK - PROBES
Measuring unit with FK1-, FK2- or FK3-connector, which is plugged into the vehicle’s fuse holder instead of the original fuse. The original fuse has to be plugged into the PROBE’s fuse holder to ensure that the measuring circuit is protected. The fuse holder and the shunt are integrated in a small aluminum casing.
Construction:
FK1-, FK2-, FK3- connector
cable with fuse = L1 (highly flexible and heat resistant)
aluminium casing with integrated shunt and fuse holder for measuring circuit protection
data cable = L2 (1…5m) with 6-pin push-pull-connector.
memory device, used for PROBE-identification and calibration data.
Caution: The maximum continuous current may be lower than the measuring range.
Please refer to the user manual.
JCASE - and MCASE - PROBES ?
Measuring unit with JCASE or MCASE connector, which is plugged into the vehicle’s fuse holder instead of the original fuse. The measuring circuit is protected by a JCASE fuse with the equivalent current valueto ensure that the measuring circuit is protected. The JCASE fuse is plugged into the fuse holder at the aluminium casing. The measuring shunt is integrated in the casing.
Construction:
JCASE or MCASE connector
cable with fuse = L1 (highly flexible and heat resistant)
aluminium casing with integrated shunt and fuse holder for measuring circuit protection
data cable = L2 (1…5m) with 6-pin push-pull-connector
memory device, used for PROBE-identification and calibration data
Caution: The maximum continuous current may be lower than the measuring range.
Please refer to the user manual.
HI – PROBES (without measuring circuit protection)
At these PROBEs the shunt has to be placed directly into the measuring circuit.
The protection of the measuring circuit has to be provided by the user.
Construction:
Shunt (type BF1 or BF2) with mounting straps (temperature range -40…+130°C)
data cable = L2 (1…5m) with 6-pin push-pull connector
memory device, used for PROBE identification and calibration data
Caution: The maximum continuous current is lower than the measuring range.
Please refer to the user manual.